Aseptic loosening continues to be a problem with total hip replacements. In cemented total hip replacement, mechanically induced loosening most often initiates at the stem-cement or cement-bone interface. And while it is widely accepted that a strong bone is desirable at the cement-bone interface, the optimal cement-metal interface is disputed for cemented femoral components. A research program is proposed to investigate: 1) the specific mechanical conditions under which the femoral stem-cement and cement-bone interfaces fail; 2) the manner in which interface failure contributes to mechanical loosening of cemented femoral hip components; and 3) the use of this information to """"""""optimize"""""""" the locations and extent of stem-cement bonding to reduce the risk of implant failure. Here, """"""""bonding"""""""" is used to describe any enhanced stem-cement interface (mechanically roughened or PMMA precoated), as compared to a smooth unbonded interface. It is the hypothesis of this work that the manner and extent of bonding of the stem-cement interface affects the overall failure (loosening) of the implant. It is further hypothesized that some """"""""optimum"""""""" configuration, consisting of regions where the stem is bonded, and regions where the stem is unbonded, will result in a significant increase in the long-term performance of the implant.

Agency
National Institute of Health (NIH)
Institute
National Institute of Arthritis and Musculoskeletal and Skin Diseases (NIAMS)
Type
First Independent Research Support & Transition (FIRST) Awards (R29)
Project #
5R29AR042017-05
Application #
6171299
Study Section
Orthopedics and Musculoskeletal Study Section (ORTH)
Program Officer
Panagis, James S
Project Start
1996-07-15
Project End
2001-06-30
Budget Start
2000-07-01
Budget End
2001-06-30
Support Year
5
Fiscal Year
2000
Total Cost
$68,038
Indirect Cost
Name
Upstate Medical University
Department
Orthopedics
Type
Schools of Medicine
DUNS #
058889106
City
Syracuse
State
NY
Country
United States
Zip Code
13210
Srinivasan, Priyanka; Miller, Mark A; Verdonschot, Nico et al. (2017) A modelling approach demonstrating micromechanical changes in the tibial cemented interface due to in vivo service. J Biomech 56:19-25
Srinivasan, Priyanka; Miller, Mark A; Verdonschot, Nico et al. (2017) Strain shielding in trabecular bone at the tibial cement-bone interface. J Mech Behav Biomed Mater 66:181-186
Srinivasan, Priyanka; Miller, Mark A; Verdonschot, Nico et al. (2016) Experimental and computational micromechanics at the tibial cement-trabeculae interface. J Biomech 49:1641-1648
Zimmerman, William F; Miller, Mark A; Cleary, Richard J et al. (2016) Damage in total knee replacements from mechanical overload. J Biomech 49:2068-2075
Miller, Mark A; Goodheart, Jacklyn R; Khechen, Benjamin et al. (2016) Changes in microgaps, micromotion, and trabecular strain from interlocked cement-trabecular bone interfaces in total knee replacements with in vivo service. J Orthop Res 34:1019-25
Goodheart, Jacklyn R; Miller, Mark A; Mann, Kenneth A (2014) In vivo loss of cement-bone interlock reduces fixation strength in total knee arthroplasties. J Orthop Res 32:1052-60
Oest, Megan E; Miller, Mark A; Howard, Karen I et al. (2014) A novel in vitro loading system to produce supraphysiologic oscillatory fluid shear stress. J Biomech 47:518-25
Mann, Kenneth A; Miller, Mark A; Goodheart, Jacklyn R et al. (2014) Peri-implant bone strains and micro-motion following in vivo service: a postmortem retrieval study of 22 tibial components from total knee replacements. J Orthop Res 32:355-61
Mann, Kenneth A; Miller, Mark A (2014) Fluid-structure interactions in micro-interlocked regions of the cement-bone interface. Comput Methods Biomech Biomed Engin 17:1809-20
Miller, Mark A; Terbush, Matthew J; Goodheart, Jacklyn R et al. (2014) Increased initial cement-bone interlock correlates with reduced total knee arthroplasty micro-motion following in vivo service. J Biomech 47:2460-6

Showing the most recent 10 out of 32 publications