A new cell separation centrifuge system is developed. It uses a centrifuge bowl equippted with a circular channel (3 cm wide and 5 mm deep) around the periphery which is interrupted by a septum so that the liquid introduced from one terminal is quantitivedly colllected from the other end. The channel is equipped with 6 inlets and outlets each connected to flow tubes which led to the outside of the centrifuge system. A set of polymer solutions of different densities is introduced through inlets 2 to 6 at 1 ml/min and collected through the respective outlets at the same flow rates. The sample cell suspention is continuously fed through the first channel at a higher flow rate of 2 - 5 ml/min and collected through the respective outlet which is open to the air. The cell in the sample suspention gradually migrate into the polymer layers and are finally suspended into the polymer layer of the same density. The preliminary results obtained from human blood buffy coat revealed that the lymphocyts and granulocytes are well resolved and erythrocytes are completely separated from white cells. CD34 cells are mainly distributed in the lymphocyte fraction (density 1.060-1070) suggesting that they may be enriched by finely focusing the dendity gradient around 1.065. The time required to process 1,000,000,000 cells are about 3 hours.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Intramural Research (Z01)
Project #
1Z01HL001053-01
Application #
6414698
Study Section
(CBS)
Project Start
Project End
Budget Start
Budget End
Support Year
1
Fiscal Year
2000
Total Cost
Indirect Cost
Name
U.S. National Heart Lung and Blood Inst
Department
Type
DUNS #
City
State
Country
United States
Zip Code
Inui, Masafumi; Fukui, Akimasa; Ito, Yuzuru et al. (2006) Xapelin and Xmsr are required for cardiovascular development in Xenopus laevis. Dev Biol 298:188-200
Cao, Xue-Li; Xu, Ya-Tao; Zhang, Guang-Ming et al. (2006) Purification of coenzyme Q10 from fermentation extract: high-speed counter-current chromatography versus silica gel column chromatography. J Chromatogr A 1127:92-6
Shibusawa, Yoichi; Takeuchi, Naoko; Sugawara, Kazusa et al. (2006) Aqueous-aqueous two-phase systems composed of low molecular weight of polyethylene glycols and dextrans for counter-current chromatographic purification of proteins. J Chromatogr B Analyt Technol Biomed Life Sci 844:217-22
Shibusawa, Yoichi; Yamakawa, Yutaka; Noji, Ryoko et al. (2006) Three-phase solvent systems for comprehensive separation of a wide variety of compounds by high-speed counter-current chromatography. J Chromatogr A 1133:119-25
Ito, Yoichiro (2005) Golden rules and pitfalls in selecting optimum conditions for high-speed counter-current chromatography. J Chromatogr A 1065:145-68