A compact bench-top model of the centrifuge enables continuous cell separation according the density. The apparatus holds a small separation disk equipped with a circular channel (8 ml capacity) interrupted by a septum. A set of isotonic Percoll media with different densities was continuously introduced at one terminal and collected from the other. Under centrifugal force field, cell suspension introduced into the proximal portion of the channel results in continuous separation of cells according to their densities. The performance of the apparatus was demonstrated on separation of human buffy coat containing nucleated cells of more than 100,000,000 among a large population (10,000,000,000) of RBC. The results indicated that the method is capable of separating a large number of nucleated cells with minimum damage for a few hours of operation where neutrophils are well resolved from lymphocytes. The method may be applied to other types of samples including cord blood, blood from small animals, cultured cells, pancreatic ? cell islets, malaria parasites, sperm cells, etc.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Intramural Research (Z01)
Project #
1Z01HL001053-03
Application #
6690472
Study Section
(LBC)
Project Start
Project End
Budget Start
Budget End
Support Year
3
Fiscal Year
2002
Total Cost
Indirect Cost
Name
U.S. National Heart Lung and Blood Inst
Department
Type
DUNS #
City
State
Country
United States
Zip Code
Shibusawa, Yoichi; Yamakawa, Yutaka; Noji, Ryoko et al. (2006) Three-phase solvent systems for comprehensive separation of a wide variety of compounds by high-speed counter-current chromatography. J Chromatogr A 1133:119-25
Inui, Masafumi; Fukui, Akimasa; Ito, Yuzuru et al. (2006) Xapelin and Xmsr are required for cardiovascular development in Xenopus laevis. Dev Biol 298:188-200
Cao, Xue-Li; Xu, Ya-Tao; Zhang, Guang-Ming et al. (2006) Purification of coenzyme Q10 from fermentation extract: high-speed counter-current chromatography versus silica gel column chromatography. J Chromatogr A 1127:92-6
Shibusawa, Yoichi; Takeuchi, Naoko; Sugawara, Kazusa et al. (2006) Aqueous-aqueous two-phase systems composed of low molecular weight of polyethylene glycols and dextrans for counter-current chromatographic purification of proteins. J Chromatogr B Analyt Technol Biomed Life Sci 844:217-22
Ito, Yoichiro (2005) Golden rules and pitfalls in selecting optimum conditions for high-speed counter-current chromatography. J Chromatogr A 1065:145-68