The principle objective of this proposal is to develop a high resolution, high detection efficiency positron emission tomography (PET) detector with depth-of-interaction (DOI) positioning that will also support multi-modality imaging (e.g., PET/MR). This detector design can be scaled to support imaging applications from mice to man. The key design features of this PET detector are the use of trapezoidal, salt crystals (TSC) and a maximum likelihood positioning method that we call statistics based positioning (SBP). In addition to the unique crystal geometry, the design will utilize silicon photomultiplier (SiPM) arrays. SiPMs are Geiger-mode avalanche photodiode devices that have very attractive performance characteristics for PET detectors, especially for PET-MR applications. In this R21 proposal, we will investigate a design tailored for small animal PET imaging. The design will support <0.8 mm image resolution and >15% absolute detection efficiency. It is envisioned that the detectors developed under this proposal will eventually be used to fabricate a very compact PET detector ring that will be compatible with operation in high field (e.g., >4.7T) MR systems. For this prototype work the TSC PET detector dimensions will be designed for a system inner ring diameter of ~6.0 cm. This diameter will support dedicated PET and PET/MR whole body mouse and rat brain imaging. The net result of this work is the development and evaluation of a new PET detector design that will provide state of the art imaging performance capabilities and that can be used as part of a compact, stand alone PET system or as part of a multi-modality imaging system (e.g., PET/MR). We believe that this design will provide an outstanding balance between performance and cost and that the design will be translatable to commercial adaptation. This proposal builds upon the previous work of the investigators developing high resolution discrete crystal PET detectors and high resolution monolithic crystal PET detectors. This new design synergistically brings together the inherent strengths of both methods, that is, modularity and excellent spatial resolution control (discrete crystals) and lower fabrication costs and inherent DOI positioning capability using single-sided readout (continuous crystals). The design is scalable to support ultra-high resolution small animal imaging;high resolution organ specific imaging;and whole-body PET imaging. In addition, this project will add to the knowledge based on how to optimize the use of SiPM devices for nuclear medicine imaging detector applications. Two specific areas in which this work will contribute are developing SiPM signal multiplexing techniques to optimize performance versus cost and developing temperature control strategies and temperature/gain dependent calibration procedures for SiPM devices.

Public Health Relevance

The overall goal of this proposal is to develop technology that will be used to advance the biological applications of PET and multi-modality PET imaging. PET is a very important imaging modality for both clinical and research applications (e.g., oncology, cardiology, neurology, drug development, biodistribution studies, cell trafficking, etc.). Further great synergism has been demonstrated when it is combined with a high resolution anatomic imaging modality (e.g., PET/CT or PET/MR). The key component of any PET system is the detector design. In this proposal, we introduce a new trapezoidal, slat crystal (TSC) PET detector that is scalable between small animal imaging and human whole body imaging. We believe that this design will provide state of the art imaging performance and an economical price point such that the design will be translatable to commercial production. Therefore while the focus of this proposal is on a specific PET detector design, the far reaching goal of this work is to develop PET imaging technology that will aid in the battle against human disease.

Agency
National Institute of Health (NIH)
Institute
National Institute of Biomedical Imaging and Bioengineering (NIBIB)
Type
Exploratory/Developmental Grants (R21)
Project #
1R21EB013716-01A1
Application #
8308188
Study Section
Special Emphasis Panel (ZRG1-BMIT-J (01))
Program Officer
Sastre, Antonio
Project Start
2012-04-01
Project End
2014-03-31
Budget Start
2012-04-01
Budget End
2013-03-31
Support Year
1
Fiscal Year
2012
Total Cost
$182,129
Indirect Cost
$57,129
Name
University of Washington
Department
Radiation-Diagnostic/Oncology
Type
Schools of Medicine
DUNS #
605799469
City
Seattle
State
WA
Country
United States
Zip Code
98195
Pierce, L A; Pedemonte, S; DeWitt, D et al. (2018) Characterization of highly multiplexed monolithic PET / gamma camera detector modules. Phys Med Biol 63:075017