The physical and biological processes governing the flow of blood are intimately responsible for safety and efficacy of all blood-wetted medical devices. The quest to design improved cardiovascular devices is however stifled by the inadequacies of current understanding of blood trauma and thrombosis. In spite of decades of experience with device design, hemotrauma research, and computational fluid dynamics modeling, it is virtually impossible to avoid deleterious hematological effects without experimental trail-and-error. Contemporary design relies upon venerable mathematical formula for blood that is more descriptive than predictive. Furthermore, we now understand that that these three phenomena are more closely coupled that previously appreciated. Indeed, previous models virtually neglected the existence of any coupling between these three processes. The objective of proposed project is to advance the accuracy and utility of a predictive model for thrombosis in blood-wetted cardiovascular devices. The research is built upon a combination of a previous model developed by the PI and colleagues for shear- mediated thrombosis and recent progress in modeling cellular-scale hemodynamics. Further incorporation of a model for synergy of platelet agonists is intended to yield a comprehensive design tool that is practical for design optimization of cardiovascular devices. Computer simulations will predict the dynamic interaction of red blood cells (RBCs) with platelets (Plts) in blood flow, and will rely upon a sophisticated theory of interacting continua that can predict the distribution of cells in any arbitrary flow path. The model will be validated and calibrated by both micro-scale computer simulations and microscopic visualization of blood cells in micro-channels. The predictive capacity of model will be demonstrated in three benchmark applications motivated by the development of cardiovascular devices for children: (1) parallel plate study incorporating various microscopic steps and crevices, (2) flow within blade tip of rotary blood pump, and (3) hydrodynamic bearing for pediatric rotary blood pump. Successful completion of these aims will produce a comprehensive computational model for blood trauma in cardiovascular devices, which we believe will contribute to the paradigm shift in the way these devices are developed: replacing trial-and-error with prescriptive bioengineering methods. Combined with computer optimization, the use of this model will greatly accelerate development of innovative new devices, and will reduce the occurrence of adverse complications. We also envision that the models will also be informative for diagnosing various clinical events, and help guide management of anticoagulation therapy.

Public Health Relevance

Cardiovascular devices that are implanted today carry a risk of un-intended blood clotting, which may cause serious injury including stroke. The purpose of this project is to create a computer simulation program that will predict when this might occur, and thereby guide developers of these devices to produce more safe and effective devices.

Agency
National Institute of Health (NIH)
Institute
National Heart, Lung, and Blood Institute (NHLBI)
Type
Research Project (R01)
Project #
5R01HL089456-03
Application #
8029501
Study Section
Bioengineering, Technology and Surgical Sciences Study Section (BTSS)
Program Officer
Link, Rebecca P
Project Start
2009-02-01
Project End
2014-01-31
Budget Start
2011-02-01
Budget End
2012-01-31
Support Year
3
Fiscal Year
2011
Total Cost
$506,772
Indirect Cost
Name
Carnegie-Mellon University
Department
Biomedical Engineering
Type
Schools of Engineering
DUNS #
052184116
City
Pittsburgh
State
PA
Country
United States
Zip Code
15213
Olia, Salim E; Wearden, Peter D; Maul, Timothy M et al. (2018) Preclinical performance of a pediatric mechanical circulatory support device: The PediaFlow ventricular assist device. J Thorac Cardiovasc Surg 156:1643-1651.e7
Blue Martin, A; Wu, Wei-Tao; Kameneva, Marina V et al. (2017) Development of a High-Throughput Magnetic Separation Device for Malaria-Infected Erythrocytes. Ann Biomed Eng 45:2888-2898
Wu, Wei-Tao; Jamiolkowski, Megan A; Wagner, William R et al. (2017) Multi-Constituent Simulation of Thrombus Deposition. Sci Rep 7:42720
Wu, Wei-Tao; Yang, Fang; Wu, Jingchun et al. (2016) High fidelity computational simulation of thrombus formation in Thoratec HeartMate II continuous flow ventricular assist device. Sci Rep 6:38025
Jamiolkowski, Megan A; Pedersen, Drake D; Wu, Wei-Tao et al. (2016) Visualization and analysis of biomaterial-centered thrombus formation within a defined crevice under flow. Biomaterials 96:72-83
Olia, Salim E; Maul, Timothy M; Antaki, James F et al. (2016) Mechanical blood trauma in assisted circulation: sublethal RBC damage preceding hemolysis. Int J Artif Organs 39:150-9
Wu, Wei-Tao; Martin, Andrea Blue; Gandini, Alberto et al. (2016) Design of microfluidic channels for magnetic separation of malaria-infected red blood cells. Microfluid Nanofluidics 20:
Wu, Wei-Tao; Yang, Fang; Antaki, James F et al. (2015) Study of blood flow in several benchmark micro-channels using a two-fluid approach. Int J Eng Sci 95:49-59
Yang, Fang; Kormos, Robert L; Antaki, James F (2015) High-speed visualization of disturbed pathlines in axial flow ventricular assist device under pulsatile conditions. J Thorac Cardiovasc Surg 150:938-44
Jamiolkowski, Megan A; Woolley, Joshua R; Kameneva, Marina V et al. (2015) Real time visualization and characterization of platelet deposition under flow onto clinically relevant opaque surfaces. J Biomed Mater Res A 103:1303-11

Showing the most recent 10 out of 25 publications